Call for papers :

Submission Last Date 31/03/2018
Status Notification Within 2 Days
Submit Paper Online

Check Paper Status

Paper Status

News & Updates

IJAERD provides Hard Copy of Published Certificates of Publication to each author.

We have started accepting articles by online means directly through website. Article submission link is given on left side

IJAERD Provide Review card, Acceptance Letter and Fee Receipt without taking any extra charges

IJAERD invites research paper from various engineering disciplines for Vol.1 Issue 12 (Dec. - 2014) issue,

Conference Proceedings

National Conference on Emerging Trends in Computer & Electrical Engineering (ETCEE - 2014) March 7-8, 2014, Organized by Atmiya Institute of Technology and Science, Rajkot

National Conference on Recent Research in Engineering and Technology (NCRRET-2015) organizing by Dr. Jivraj Mehta Institute of Technology, Mogar-Anand

National Conference on Emerging Trends in Computer, Electrical & Electronics (ETCEE - 2015), March 13-14, 2015, Organized by Atmiya Institute of Technology and Science, Rajkot

Paper Details

Paper Title
Short-circuit analysis of Industrial plant
Short circuit analysis is one of the power system analysis method and which is performed to size the power system and protective devices as well as find electrical parameters for power system protection design. Additionally, it is also performed at regular interval of time for troubleshooting as well as decides setting of relays with considering load expansions. In industrial plant, it is performed during planning stage as well as when remarkable change occurs in load as well as generation. . In this paper, the short circui analysis of 6.6 kV industrial plants is presented using Electrical Transient Analysis Program -7.5.5(ETAP). The plant is supplied by two in plant generators (2*16.5 MW Existing and 11.8 MW-newly installed). The external grid supply is used for black start of TGs. Existing load is raised from 17.5 MW to 24 MW, after expansion. So this analysis is performed to check sizing of different protective devices with generation surplus and operating philosophy selection.G2+G3 configuration short circuit current is recommended for relay coordination setting and for device duty varifications.
Short circuit Analysis, ETAP, ANSI method, IEC method, Classical Method.
Others Details
Paper Id : 46787
Author Name : Parmar Ashokkumar Bhikhubhai
Volume/Issue No : Volume 05 Issue 03
Page No : 41-49
DOI Number : DOI:10.21090/IJAERD.46787
Publication Date : 2018-03-07
License : This work is licensed under a Creative Commons Attribution 4.0 International License.
website :
Impact Factor : 4.72, SJIF-2016
ISSN Details : eISSN: 2348-4470, pISSN:2348-6406